Set up a barcode scanner for the SmartFACT scan field

The settings every keyboard scanner needs: Enter as the suffix, no prefix, the right keyboard language, and the identifier a GS1 label needs.

Review edition · 10 November 2026 · For Owner, Supervisor

On this page

This page is for any barcode scanner that types into a computer, tablet or handheld as a keyboard does, used with the scan field in SmartFACT products. It gives the few settings that matter and the reason for each. It was written from how the scan field itself behaves and from the makers' documents named on the three pages below, read on 10 November 2026. It has not been checked on a scanner, and it names no model. Finish with the ScannerBench check at the end, on the station where the scanner will be used.

Each maker has its own name for the same settings:

What the scan field expects

A scan is the characters the scanner types, followed by one key that ends it. That key is Enter, unless the station has been set to Tab. ParcelOffice, for one, lets a station choose.

The scan field takes those characters exactly as they arrive. Nothing is trimmed, corrected or changed from small letters to capitals. A space, an extra character at the front or one changed letter is part of the code, and a code that differs by one character does not match.

If the scanner ends a scan with the other key, the field clears the scan, takes nothing and says which key it expects. A scanner that sends no end key leaves the code sitting in the field until someone presses Enter.

The settings that matter

  • How the scanner presents itself: a keyboard. A scanner set up as a serial device types nothing into a browser.
  • Suffix: Enter, once. Enter ends the scan. Use Tab only at a station that is set to Tab.
  • Prefix: none. A prefix arrives as the first characters of every code.
  • Keyboard country or language: the same as the computer's keyboard. The scanner sends key positions, and the computer decides which character each one is.
  • Anything that edits the code: off. Settings that remove leading zeros, change case or reformat a code change what the field receives.

Keyboard language

A scanner that works as a keyboard sends the positions of keys. The computer turns each position into a character using its own keyboard layout. When the scanner is set for one country and the computer for another, letters and digits usually arrive unchanged and punctuation does not. Between a United States and a United Kingdom layout, @, " and # are among the characters that change.

If your codes hold only capital letters, digits and hyphens, a wrong country setting can go unnoticed for months. Set it correctly anyway: the first code with other punctuation will fail.

Bluetooth or USB

A scanner on a USB cable, or on a wireless receiver plugged into USB, is a keyboard as soon as it is plugged in and set to keyboard mode. There is nothing to pair.

A Bluetooth scanner must be paired in its keyboard mode. Makers call this HID. A scanner paired in its serial mode connects and beeps, and types nothing. After a Bluetooth scanner reconnects, scan one known label before going on.

A mobile computer with a built-in scanner needs its scanning software set to type into the browser. On a Zebra device that software is DataWedge.

If characters go missing from long codes, the scanner may be typing faster than the device accepts. Zebra and Datalogic each have a setting that adds a delay between characters, named on their pages.

GS1 labels need the scanner's identifier

A supplier's GS1 label holds several fields in one barcode, such as an item number and a lot. Where a field of no fixed length is followed by another field, the barcode holds an invisible separator between them.

A scanner that works as a keyboard sends that separator as a control key, Ctrl and the right bracket. In a browser field a control key leaves no character behind. The separator is lost, and nothing in the remaining text says the code was a GS1 label.

So LotTrail recognises a scanned GS1 label by its prefix. A scanner can be set to send a short identifier in front of each code that says what kind of barcode it read: ]C1 for GS1-128, ]d2 for GS1 DataMatrix and ]Q3 for GS1 QR Code. Makers call it the AIM identifier or AIM ID. The setting that sends it is:

Maker and setting What it prefixes
Zebra DataWedge: Code ID Type, set to Code ID Type Aim Every code
Datalogic: GS1-128 AIM ID, set to Enable GS1-128 labels only
Datalogic: Global AIM ID, set to Enable Every code
Honeywell: not named in the document this handbook was written from See the Honeywell page

Two cautions:

  • A setting that prefixes every code changes your own codes too. Every other scan field takes the identifier as the start of the code, and the code no longer matches. Use such a setting only on a scanner kept for reading suppliers' labels, or use a setting limited to GS1 labels where the maker has one.
  • The identifier does not bring the separator back. When a label has a separator between two fields, LotTrail sees the key, reads nothing and keeps the scan as typed text, so that one field is never run into the next. Enter the lot by hand. A label whose only field of no fixed length comes last, such as an item number followed by a lot, has no separator and is read.

The steps in LotTrail are in Save a bounded investigation.

Check it with ScannerBench

ScannerBench shows exactly what a scanner sends: each character, each key and how the scan ended. It needs no account, uploads nothing you scan and changes no scanner setting.

  1. On the station's own computer, tablet or handheld, in the browser the station uses, open ScannerBench.
  2. Choose Start capture. Leave How a scan ends at Enter, or choose Tab for a station that is set to Tab.
  3. Scan a label whose exact text you know. The capture should end by itself, by the Enter key. If you have to finish it by hand, the scanner sent no end key: set its suffix.
  4. Go on to Inspect and compare and enter the label's text as Expected text. An exact match means every character arrived as printed.
  5. If it differs, ScannerBench shows where. Extra characters at the front are a prefix. Changed punctuation points to the keyboard country. Missing leading zeros point to a setting that edits the code.
  6. Open the key events when something is still unexplained. A Tab key, or a control key such as the GS1 separator, shows there even though it leaves no character.

At Hartwell & Pryce Engineering's Brighouse works, Sarah Hughes checks the scanner for the bench where Sam Ashworth works. She enters WO-004182 as the expected text and scans the work order label. ScannerBench shows WO-004182, ended by the Enter key, an exact match with both zeros kept. She then scans the longest code the bench uses, and one supplier label to see whether an identifier arrives in front of it.