This page covers one Honeywell scanner, the corded Voyager XP 1470g, used as a keyboard with a SmartFACT scan field. Each setting is named as Honeywell names it. Read the general scanner page first for what the scan field expects.
It was written from one document: Honeywell's Voyager XP 1470g Series Corded Area-Imaging Scanner Quick Start Guide, VG1470-EN-QS-01 Rev B, dated 9/24, read on 10 November 2026. That guide refers to the scanner's full User Guide for its complete lists. Honeywell's document site asked for a sign-in before showing the User Guide when this page was written, so it was not read. This page therefore names only the settings in the quick start guide, and says where it stops. It has not been checked on a scanner, and it makes no claim about any other Honeywell model.
How settings are made
The quick start guide prints a programming barcode for each setting below. Scanning the barcode makes the setting. This page gives the names to look for; the barcodes are in Honeywell's guide.
Honeywell also names EZConfig for Scanning, which it describes as an online configuration software tool, available from its website, for the scanner's additional features. This page gives no EZConfig steps, because none are in the document it was written from.
Connect it by USB
The quick start guide shows four connections: USB, Keyboard Wedge, RS232 Serial Port and RS485. For a station that runs in a browser, use USB.
The scanner must then type as a keyboard. The quick start guide does not print the barcode that chooses between the scanner's USB modes. If nothing arrives in ScannerBench after you plug the scanner in, it is not working as a keyboard, and the setting to change is in the User Guide.
A scanner that was set up for another system can be returned to Honeywell's own settings with the Standard Product Defaults barcode, which the guide says resets all standard product default settings. Every setting on this page then has to be made again.
Keyboard Country
Under Keyboard Country, scan the barcode for the keyboard layout of the station's computer. The default is USA (Default). For a computer with a United Kingdom keyboard, the guide's barcode is Great Britain.
Honeywell says that by default the scanner uses national replacements for twelve punctuation characters, among them # $ @ [ ] \ | ^ { } ~. If your codes hold any of them, include one such code in the ScannerBench check.
Suffix
The guide's Suffix section has three barcodes:
- Add CR Suffix sends a carriage return, the Enter key, after each code. Use it at every station that ends a scan with Enter.
- Add Tab Suffix sends a tab after each code. Use it only at a station that is set to Tab.
- Remove Suffix removes the suffixes. Scan it first when you are not sure what the scanner already sends.
Prefix
Set no prefix. A prefix arrives as the first characters of every code.
The quick start guide has one prefix barcode, Add Code ID Prefix To All Symbologies (Temporary). It puts a Code ID in front of every code the scanner reads. Do not scan it for a station.
For a supplier's GS1 label, LotTrail looks for an identifier at the front of the scan: ]C1, ]d2 or ]Q3. The quick start guide does not say what a Code ID looks like, and it names no setting for that form of identifier. It refers to the User Guide for the complete list of Code IDs. So this page cannot name the Honeywell setting that sends it. To see what your scanner puts in front of a GS1 label, scan one in ScannerBench.
Function Code Transmit
The guide's Function Code Transmit setting is Enable by default. Honeywell says that with it enabled the scanner transmits function codes that are in the scanned data, and that in keyboard wedge mode the code is converted to a key code first. The charts of function codes are in the User Guide.
Leave it at its default. The general page explains how the separator inside a GS1 label is lost when a scanner sends it as a key. Whether this setting governs that separator is a matter for the User Guide's charts. ScannerBench's key events show what your scanner sends.
A scanner that changes its codes
If a scanner that was used elsewhere cuts or rearranges codes, it may hold a data format. The quick start guide has a Clear All Data Formats barcode under Data Format Editor Instructions. Do not enter a data format for a station: the scan field needs the code exactly as printed.
Where this page stops
It does not cover:
- the setting that makes the scanner type as a USB keyboard;
- the identifier LotTrail looks for in front of a GS1 label;
- a delay between characters;
- the cordless Voyager XP 1472g, Bluetooth, or any other Honeywell scanner or mobile computer.
Each is a matter for Honeywell's User Guide for the model in your hand.
Check it with ScannerBench
- On the station's own computer, in the browser the station uses, open ScannerBench.
- Choose Start capture and scan a label whose exact text you know.
- The capture should end by itself, by the Enter key. Go on to Inspect and compare, enter the label's text as Expected text and look for an exact match.
What each result means on this scanner:
| ScannerBench shows | Look at |
|---|---|
| Nothing arrives | The connection: the scanner is not typing as a keyboard |
| The text arrives and the capture does not end | Add CR Suffix |
| A Tab key in the key events | Remove Suffix, then Add CR Suffix |
| Changed punctuation | Keyboard Country |
| Extra characters at the front | A prefix or Code ID has been added |
| Characters cut or moved | A data format |
A match shows what this scanner sent to this browser on this day. It is not a certificate for the scanner. Finish with the product's own scanner check at the station and one real scan.