Skip to content
SmartFACT HelpHandbooksWatch and practise
Handbooks: FactorySpec

How to use more of a component above a length

Use a starter rule to add a component line with one count above a length limit and another at or below it.

Review edition · 16 November 2026 · For Author, Reviewer

On this page

Some components are counted by size: a wide frame takes three brackets where a narrow one takes two. The starter rule Use more of a component above a length adds a component line whose count is one figure when a length is over your limit and another figure at or below it.

Use the starter rule

You need the Author role, and the family needs a saved draft that the evaluator accepts, with at least one length input and one component whose Dimension profile is a count only. The rule goes into the draft's next revision. No evaluation uses it until a separate Reviewer approves a release that contains it and activates it, and every result stays an evaluation result.

  1. Open Product families and choose the family in Open a family.
  2. Under Starter rules, find Use more of a component above a length. It is in Component list, and also under Recommended. You can also type a word from its title in the search box above the cards.
  3. Fill in the blanks in the card's sentence, "Use … … when … is greater than … mm. Otherwise use …":
    • Count above the limit: how many each unit takes when the length is over the limit, from 1 to 9,999.
    • Component: one of the family's components counted without dimensions, shown by its description and code.
    • Length: one of the family's length inputs.
    • Limit: the length in millimetres, as your product expert gives it. A unit exactly at the limit takes the other count.
    • Count otherwise: how many each unit takes at or below the limit. It must differ from the count above the limit.
  4. Choose Use this rule. The button waits until every blank has a value.

FactorySpec saves the draft's next revision with one new line at the end of Component list. It is the same line you would get by choosing Add component line in the engineering model and entering the count as a choice between the two figures, then choosing Save draft. No AI is asked. Above the cards, the page says which starter rule the revision began from.

Save or discard any unsaved change in the engineering model first: the cards wait while the editor has one. If someone saved a newer revision of the draft after you opened the page, the card is refused: reload the page, check what changed, then use the card again.

Where SmartFACT Automation is connected to FactorySpec, you can also arrive here from New requirement there, which offers the cards of the family whose draft changed most recently. Its Use this rule makes nothing: it opens Product families on that family with this card alone and its blanks filled in. Check the blanks, then choose Use this rule on the page. See every starter rule shows all the cards.

This card sets a count, which plain English does not describe in FactorySpec, so Reword with AI refuses it even where plain English is switched on. Use the card, then change the figures in the engineering model if you need to.

What the rule does

For a unit whose length is over the limit, the new line lists the component with the count above the limit. For every other unit it lists the count otherwise. A unit without that length, where the length is optional, takes the count otherwise. The family's other lines are unchanged.

For Frame assembly FA-300 at Brighouse works, "Use 3 Support clip (CLIP) when Finished external height is greater than 1800 mm. Otherwise use 2" lists three support clips for a frame 2,000 mm high and two for a frame exactly 1,800 mm high.

Correct the independent cases

A starter rule saves no case and changes none, because an expected component list is your product expert's to state from the engineering source: FactorySpec never works it out for you. The family's existing cases now expect a component list without the new line, so they no longer pass, and the page says the draft is not ready for independent review. Under Independent cases in the engineering model:

  • add the new line to the expected component list of every valid case, with the count the source gives for that case's length;
  • include one case just over the limit and one exactly at it, so both counts are checked;
  • give each change an engineering basis that names the source.

Save the draft and read the proof. Where actual and expected differ, settle it from the source, not by copying what the evaluator returns.

Review and activate it

Choose Run cases and request review. The candidate freezes the model, the cases and a bounded comparison with the active release. A Reviewer who did not contribute to the model or its cases checks it and chooses Approve this candidate, then activates the release with a recent second factor. Review a candidate describes the review. A rule from a starter rule is reviewed like any other, and an accepted result remains an evaluation result, not a manufacturing approval.

Change it later

Nothing about a starter rule makes its rule permanent. Change the line's figures or limit in Component list, or remove the line, and save the change as a new revision. Correct the cases, request review and activate the new release in the same way. Results already accepted keep the release and inputs they were accepted with.

If the card is refused

A refused card saves nothing, and the message says why:

  • "Not done: reload the current draft before making this change." Another author saved the draft after you opened the page.
  • "Not done: this card has changed since the page was read." The draft's inputs or components, or FactorySpec's starter rule, changed. Reload the page and fill the card in again.
  • "Not done: use a different count above the limit from the count otherwise." Both counts are the same, so the rule would change nothing.
  • "Not done: the engineering model already has this rule." A line already lists the same component with the same counts and limit.