Use this procedure with an issued unit, the correct lookup reference and your own Operator sign-in. Check the actual station name before claiming work. Keep the physical unit with its record throughout the attempt.
Claim and follow the route
Open Station, choose the enrolled station and identify the work. Compare the displayed unit, job and release with the physical work and claim the attempt. A live claim at another station must be handed over through the proper process; do not work in parallel on two tabs.
Read the current step's instructions, images and parameters. WorkSteps determines the current step from mandatory requirements and their prerequisites. You may inspect other steps, but that does not allow future-step evidence to be recorded early.
Supply the evidence actually requested
- For an acknowledgement, confirm only after doing or checking the stated work. A negative answer is retained and holds the attempt.
- For text, enter the required observation within the displayed bounds. Blank or unsuitable text cannot satisfy it.
- For an exact identifier, scan or enter the physical value. Matching preserves spaces and case. The expected identifier is deliberately not displayed for copying.
- For a photo, upload the correct image for this requirement and wait for it to be ready before submitting. A photo for another requirement or an unavailable file cannot satisfy this one.
- For a supervisor attestation, ask the Supervisor. The station cannot submit it in their place.
Wait for the server's saved result after each item. Rejected, waiting and uncertain outcomes are different from saved evidence. An observation for an already satisfied or future requirement is refused.
Stop, pause or complete
Use Problem with this step when the instructions or physical work disagree, explaining the issue. A Supervisor must resolve the resulting hold. Pause before an agreed handover or interruption. Keep any physical hazard or quality containment under the site's normal controls.
When every mandatory requirement is satisfied, inspect Review and complete. Submit completion once and wait for the completion identity. Missing requirements, active holds, source changes or withdrawn instructions prevent completion.
If the connection fails, stop entering evidence and use connection guidance. A reference copy cannot establish current execution status. For transfer or corrections, use holds and handovers.