# When the network drops

What FactorySpec's pages show when the connection is lost while you save, evaluate, accept or record, what is kept, what is sent again and what to check before you press anything again.

Source: https://help.smartfact.ai/manuals/factoryspec/when-the-network-drops

Review edition: 16 November 2026

Roles: owner, author, reviewer, supervisor, operator

This page is for when the computer you work on loses its connection to FactorySpec while you save a draft, evaluate or accept a unit, generate a pack, record a handover or look up a result. FactorySpec has no offline mode: it records nothing while your device cannot reach it, it keeps nothing on the device, and it sends nothing again by itself when the connection returns. What FactorySpec had already recorded stays on its server. Whatever the connection did, every result remains for evaluation only and is not approved for manufacture.

## What the pages show

FactorySpec does not watch whether your device is online. When something you do gets no answer, it says so under the button or field you used.

- **A button that records something**, such as Save draft, Run cases and request review, Create family draft, Evaluate configuration, Accept this exact result, Generate engineering pack, Record handover evidence, a withdrawal or Connect OrderRun, first shows "Waiting for the server to record this action…". With no answer, at once or after 15 seconds at most, it shows **Check the original request before continuing**: "The answer did not confirm what happened. No action is sent again automatically. Keep this page open while you check the original request." The **Request reference** and a **Check original request** button follow. The press may have been recorded before the connection went, or not: the page cannot tell which.
- **While that request is not settled**, FactorySpec's other buttons on the page are unavailable, and the browser asks before you reload the page or leave it.
- **The page after a recorded action.** A recorded action says "The server has recorded this action." The page then reads the current records again, or opens what you created. If that gets no answer, it says under the button: "The connection was lost. This was recorded, but no answer came back from FactorySpec before this page could show it. Reload this page to see it before you go on.", with **Reload this page**. That button only reads the page again; it sends nothing. While the connection is still down, it says "The connection is still lost. This was recorded, but this page does not show it yet." Once FactorySpec answers, it says "The connection is back. This page now shows what FactorySpec has recorded." A new family appears in the list under Open a family.
- **Choosing a family** on Product families or Configure a unit: "The connection was lost. No answer came back from FactorySpec, and nothing was changed. Try again when the connection is back."
- **Open sample workspace, Return to production site or Create site**: "The connection was lost. No answer came back from FactorySpec, so it is not known whether this was saved. Reload this page to check before you try again.", with **Reload this page**. While the connection is still down, it says "The connection is still lost." Once FactorySpec answers, it says "The connection is back. This page now shows what FactorySpec has recorded: check whether what you sent is there before you try again."
- **Result lookup**: "The current result status could not be checked. Do not treat the previous result or a saved file as current approval." An unknown status is never shown as current.
- **Other checks** keep their own words and change nothing: the activation comparison ("The activation comparison could not be prepared. No active release was changed."), Recheck retained calculation ("The retained calculation could not be rechecked. No result or authority has changed.") and, on Service health, the diagnostic ("Not done: no answer came from FactorySpec. Check the connection, then try again.").
- **An imported file**: "The upload answer was not confirmed. Check this original request before sending it again. Stay on this page while it is unresolved.", with **Check original upload**. An import only prepares a preview for you to review: the draft changes only when you choose Save imported draft.

A page you open from the menu, and a pack download, is loaded by the browser itself, which shows its own page when there is no connection.

## What is kept, and for how long

Nothing is kept on your device. Values you have typed into a form or the model editor, and not yet recorded, exist only on that open page: reloading or closing it loses them. An unsettled request is also kept only on that open page.

On FactorySpec's server:

- **An evaluation preview** can be accepted until its **Review expires** time, 15 minutes after Evaluate configuration. After that the page says "This review expired. Evaluate again before accepting." Your inputs stay in the form while the page is open.
- **Recent verification** means a second-factor check in SmartFACT Accounts within the last five minutes. If the connection was gone for longer, an action that needs it is refused until you verify again. Saving and submitting a draft do not need it.
- **Everything recorded** (drafts, releases, results, packs, handovers and follow-up) stays as it was recorded. A lost answer never removes or changes a record.

## When the connection returns

Check before you press anything again.

1. Where the page offers **Check original request**, press it. FactorySpec looks up that exact request and sends nothing new. If it was recorded, the page shows the recorded outcome and then the current records. If it was refused, you see "Not done:" and the reason. If FactorySpec has no record of it, **Retry the same action** appears: it sends the same request again, with the same reference, and FactorySpec records it once.
2. For an import, press **Check original upload**. If the server has not recorded the upload, **Retry original upload** sends the same file and request again.
3. Where the page offers **Reload this page**, press it and read what the page now shows.

If you have left or reloaded the page, the request reference and its check are gone, because FactorySpec does not keep them on the device: a request can carry engineering details, which stay off the device. Pressing the button again sends a new request, but FactorySpec recognises it. When you send the same thing again for the same record, and what you recorded the first time still stands, it answers with that first record, says "so nothing new was recorded", and records nothing new:

- **Create family draft** with the same name and description opens the family you created: "You had already created this family draft, so nothing new was recorded." Once a draft has been saved in it, or it has been renamed, the same name makes a new family.
- **Evaluate configuration** with the same unit's exact inputs and source references shows that unit again. If it was not accepted yet, its evaluation is shown, checked again against the active release, and you can accept it: "You have already configured this unit with these exact inputs, so nothing new was recorded." If it was accepted, the page names its result, with a link to open it: "You have already configured this unit with these exact inputs and accepted its result FS-..., so nothing new was recorded." The same applies to preparing a remake from the same result.
- **Generate engineering pack** for the same result and purpose, while the result's standing is unchanged, lists the pack you generated: "You had already generated this pack, so nothing new was recorded."
- **Record handover evidence** with the same pack, receiver, reference, outcome and observed time names the report you recorded and whether another Supervisor has reviewed it: "You had already recorded this handover, so nothing new was recorded."
- **Everything else records nothing twice.** Accepting the same preview a second time is refused with "result already accepted". Saving or submitting a draft again is refused because its revision has changed, and a second withdrawal, review, connection or opening is refused because it is already done. Recording the same follow-up again records it on the same follow-up item.

Real second records still go through. Another person's press is their own. A second handover with its own observed time, outcome or reference is a new report. A pack records a new standing once the result is held, withdrawn or cleared. Two physical units can have exactly the same inputs: when Configure a unit answers with the unit you configured, choose **Configure another unit with these inputs** for a separate unit. Giving each unit its own Source unit reference also keeps them apart.

## Between OrderRun and FactorySpec

Where an Owner has connected OrderRun, the two servers talk to each other, so your own device's connection does not matter. If OrderRun gets no answer to a question about a unit, it asks again with the same request. FactorySpec answers a repeat with exactly the answer it kept, evaluates nothing again and makes no second result. A notice that a result OrderRun was given has been withdrawn, held or replaced waits on FactorySpec and is sent again until OrderRun has received it. While OrderRun is disconnected, the notices wait and nothing is sent.

## What a Supervisor sees

FactorySpec does not show anyone that a device has lost its connection, and a request still unsettled on someone's device shows nowhere else. To find out what was recorded, open the record itself: the family in Product families, the result in Results, or the handover and its follow-up in Engineering handover. Owners, Reviewers and Supervisors can also read Activity, which lists each recorded action with when it was recorded. A refused action records nothing there.

Read [Configure and accept](/manuals/factoryspec/configure-and-accept) for the acceptance checks, and [Issue packs and record handover](/manuals/factoryspec/packs-and-handover) for packs and handover evidence.
