# When the network drops

What the inspection station shows when the connection is lost, what the page keeps, how to check the original action when it returns, why a reading is never recorded twice, and how to take the station back when its control lapses.

Source: https://help.smartfact.ai/manuals/checkstation/when-the-network-drops

Review edition: 16 November 2026

Roles: operator, supervisor

This page is about the device at the inspection station losing its connection to CheckStation while you work. CheckStation has no offline mode: a reading, a start or a completion is recorded only when CheckStation answers, and nothing is stored on the device to be sent later. The page keeps only the one action that was waiting for its answer, and only while the page stays open. For an uncertain answer on a working connection, read [station problems](/manuals/checkstation/station-problems).

## What the station shows

What you see depends on what you pressed:

- **A link, or Find unit:** under the link or the scan field: "The connection was lost. No answer came back from CheckStation, and nothing was changed. Try again when the connection is back." Nothing was recorded. Press or scan again once the connection is back; the next page that opens ends the message.
- **A reading, and every other station action** (Acquire station, Confirm unit and start, Lock and release station, Resume this attempt, attaching evidence, Complete this attempt, Raise a concern and hold the unit): "Waiting for the server to acknowledge this action…" while it waits. When no answer comes, at most 15 seconds later, the page shows **Check the outcome before continuing**: "The original action is retained on this page. A missing reply does not mean the action failed. Stay on this page and reconcile its receipt.", the command's number and **Check original receipt**. These never show the connection message as well.
- **Review before starting:** "The preparation response was lost. No inspection has been started. Identify and prepare the unit again." A preparation records nothing on the unit.
- **Inspect and prepare file** for evidence: "The preparation response was lost. No attachment was confirmed. Prepare the file again before attaching it."
- **A document or label sent to print:** "The print response is uncertain. Keep this page open and reconcile the original intent." The dialog cannot be closed until the print is settled. Its button counts down, "Check original intent in 30s", and then reads **Check server job status**, which asks about the same print.
- **A form on an office page,** such as Enrol station on Team and stations: "The connection was lost. No answer came back from CheckStation, so it is not known whether this was saved. Reload this page to check before you try again." with **Reload this page**, which sends nothing again. While the connection is still lost it says "The connection is still lost." Once it is back it says "The connection is back. This page now shows what CheckStation has recorded: check whether what you sent is there before you try again."
- **The page catching up after something was recorded.** Once CheckStation has recorded a station action (after **Check original receipt** too), **Export new records** for LotTrail, or **Save read permission** or **Confirm withdrawal** on Evidence permissions, the page reads its records again. If that read gets no answer, the message goes under the button you pressed: "The connection was lost. This was recorded, but no answer came back from CheckStation before this page could show it. Reload this page to see it before you go on." with **Reload this page**, which only reads. What you pressed is recorded, so do not do it again. A station action still shows "Recorded." under its button, and Evidence permissions still says "Permission request recorded. Review the current permission history below." while the history does not show it yet. While the connection is still lost the message says "The connection is still lost. This was recorded, but this page does not show it yet. Reload this page once the connection is back." Once it is back it says "The connection is back. This page now shows what CheckStation has recorded." and the page brings it into view.

While **Check the outcome before continuing** is shown, the page sends no other action, the scan field is paused, CheckStation's own links do not open, and the browser asks you to confirm before you leave or reload the page.

CheckStation does not say that the device is offline before you press something. A page that is already open stays as it was.

## What is kept, and for how long

The action that was waiting for its answer, with what you entered, is kept in this page's memory only: CheckStation never writes readings or a unit's source details into the browser's storage. Reloading the page, closing the tab or leaving the page loses it from the page, and the page then shows what CheckStation recorded. A reading typed into its field but not yet answered is not recorded, and a reload clears it.

Nothing is sent again by itself when the connection returns.

## When the connection returns

Choose **Check original receipt**. It asks CheckStation about the same action, under its original number, and never starts a new one:

- "Recorded.": CheckStation has it. The page refreshes and shows the reading, the start or the decision. If the refresh gets no answer, the page says so under the button and offers **Reload this page**, as above.
- **Not done:** with a reason: the action reached CheckStation and was refused. Deal with that reason. For example, a reading that was already recorded says "Not done: this reading has already been recorded. The page now shows it."
- **Retry the same command** appears beside **Check original receipt**: CheckStation has no record of the action. The retry sends the same action again, with the same number and the same entry, never a second one.

If CheckStation still cannot be reached, the panel stays. Check again in a moment.

## If the page was reloaded before the check

Then this page cannot check that action any more. Read what the page shows before entering anything again:

- **A reading:** each recorded reading shows under its check, as "Reading 1 · manual entry" with the time CheckStation recorded it, and the check offers a field only for a reading still to be recorded. CheckStation records one reading for each check and repetition: entering the same one again is refused with "Not done: this reading has already been recorded. The page now shows it."
- **Confirm unit and start:** if the inspection started, scanning the unit shows **Open existing attempt** with its number. Starting it again is refused: "Not done: this unit already has an inspection in progress. Open that attempt instead of starting another."
- **Complete this attempt:** a completed inspection is no longer in progress, and completing it again is refused.
- **Raise a concern and hold the unit:** a concern that was recorded is listed under **Unit holds** on the attempt. Raising the same concern again, in the same words, while it is still open records nothing: "Not done: you have already raised this concern about this unit, and it is still open, so no second hold was recorded. It is listed under Unit holds." A concern in other words is recorded as a hold of its own.
- **Acquire station:** the station bar says "Station control acquired" if it was, or "No station control" if not.

## If station control lapses

Station control lasts ten minutes from the last action CheckStation accepted at the station: **Acquire station**, starting or resuming an inspection, a reading, attaching evidence or completing. Each accepted action starts the ten minutes again; a refused one, opening a page or checking a receipt does not. A connection lost for longer than what is left of the ten minutes therefore comes back to a locked station. When the time is up the page shows **Station idle lock**: "The last acknowledged activity has reached the station's idle limit. Obtain a fresh view and reauthenticate before recording more work." From then on CheckStation refuses every action that needs station control from this sign-in, acquiring the station again included, with "Not done: station control lapsed, because nothing was recorded at the station for ten minutes. Sign out and sign in again with your second factor, take over this station, then resume the inspection with a reason. Everything already recorded is kept." Nothing already recorded is lost, and the inspection stays open.

To carry on:

1. Choose **Sign out** in the menu, then sign in again with your second factor. Once a browser has shown the inspection station, SmartFACT Accounts asks for your own email address and password at that sign-in, so the person signed in before cannot be signed back in by mistake.
2. Open the inspection station and choose the same station under **Named station**. It shows "Current control:" with your name. Tick **Take over existing station control (fresh authentication required)** and choose **Acquire station**. Taking over needs a second-factor check from the last five minutes.
3. Scan the unit and choose **Open existing attempt** with its number. Under **Resume under this station**, give the reason in **Control transfer reason** and choose **Resume this attempt**. Until you do, a reading is refused with "Not done: another station now controls this inspection. Resume it under this station, with a reason, before recording."

The readings already recorded stay with the inspection.

If **Check the outcome before continuing** is still on the page when control lapses, choose **Check original receipt** first: checking an action needs no station control, so it still answers after the lapse. **Sign out** does nothing until that action is settled, and **Refresh station control** stays unavailable. CheckStation keeps the waiting action only on this page, so a new sign-in cannot bring it back: settle it, or note its command number, before you sign out.

## While the connection is down

Keep the unit at the station and identifiable until its inspection is recorded. A reading counts only once CheckStation shows it under its check. If you measure while the connection is down, note the value, the instrument and the time as your site's procedure requires, and enter it when the connection is back. CheckStation records the time it received each reading, not the time it was measured.

## What the Supervisor sees

CheckStation does not show anyone that a device has lost its connection. A reading, a start or a completion appears only once it has been recorded. While the station is locked, the overview still counts the unit under **In progress**, and **Open attempts** on the station page lists it with the time it started. Choosing the station under **Named station** shows "Current control:" with the person and a "last active" time, which is when CheckStation last accepted an action there. A resumed inspection lists "inspection control transferred", with its reason, under **Recorded decisions and events**.

A reading entered wrongly after the connection returned is put right with a [transcription correction](/manuals/checkstation/transcription-corrections), and each open hold, a concern in other words included, is resolved by a Supervisor under **Unit holds**, with **Review resolution of this hold** and its own reason.