Inspect and complete one bracket
Acquire a station, scan a unit, correct an invalid entry and complete its two approved checks.
For operators
Operator access is required. The recorded site, people, units and method are fictional. Approved requirements and registered source data are prepared before this lesson.
Read these instructions on any device. Watch or practise a chapter on a desktop or laptop, with a desktop or mobile application layout. Demonstrations use sample data and simulated scanners.
Inspect and complete one bracket
- Open the inspection station
Open the inspection station.
You are signed in as Sam, with operator access only. The fictional site has a separately approved bracket inspection plan.
- Choose your physical station
Choose your physical station.
Choose Inspection bench 1, where you are doing the work.
- Take control of the station
Take control of the station.
Acquire the named station before starting an inspection. This does not start a unit.
- Focus the unit scanner field
Focus the unit scanner field.
Scan the unit in front of you. This demonstration enters a fictional barcode through the same keyboard scanner field.
- Scan the unit
Scan the unit.
The scan looks up the registered unit and its order details. It does not create or release a unit.
- Review the unit and selected checks
Review the unit and selected checks.
Check the unit, order, drawing and selected checks against the physical work. Approved rules have selected the checks.
- Confirm the physical unit
Confirm the physical unit.
Confirm only the unit you have physically checked.
- Start this inspection
Start this inspection.
The server starts one inspection using the approved plan and the confirmed unit.
- Open the started inspection
Open the started inspection.
Record each required observation in the unit and precision shown.
- Enter a wrongly formatted reading
Enter a wrongly formatted reading.
A comma is not accepted as the decimal separator. This example demonstrates the refusal.
- See the entry refused
See the entry refused.
No observation was saved. Correct the entry from your actual reading; do not change the measurement to make it pass.
- Enter the actual millimetre reading
Enter the actual millimetre reading.
Use a full stop and enter the observed 10.1000 millimetres. This equals the approved upper limit.
- Record the numeric observation
Record the numeric observation.
The exact reading is retained. Continue with the next required check.
- Open the visual finish check
Open the visual finish check.
Follow the approved visual method for this physical unit.
- Record the observed finish
Record the observed finish.
Choose Pass only when the observed finish meets the approved method.
- Save the finish observation
Save the finish observation.
The finish observation is retained with this inspection.
- Review completion
Review completion.
All required observations must be present. A failed check can be recorded and completed, but its hold remains.
- Record the completion reason
Record the completion reason.
Describe the completed inspection.
- Complete this attempt
Complete this attempt.
Check the resulting status. Completion and release are separate decisions.
- Review the retained source details
Review the retained source details.
This example has conforming observations and no further release requirement, so it is released. The approved plan and source details stay attached to the record.
Check the current release status before moving the unit on. A PDF, scan or completed attempt alone is not release authority.